Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12
Figure 8.21
I. Optional Blower
The GFK-160A Blower has been designed to circulate
room air through the appliance to enhance heat output.
The GFK-160A blower system operates on 120 VAC, 60
Hz power. This is available through a receptacle in the
factory installed junction box. The junction box is mounted
in the bottom of the appliance behind the access panel. A
variable speed control is provided with the blower system
to provide quiet forced air flow at the desired speeds. A
temperature sensor switch, which automatically turns the
blower ON/OFF, is also provided with this kit.
Compare contents of carton with the actual parts received.
If any parts are missing or damaged, contact your dealer
before starting installation. Do not install a damaged
blower kit. See Figure 8.21.
Installation precautions
The GFK-160A Blower kit is tested and safe when
installed in accordance with this installation manual. It is
your responsibility to read all instructions before starting
installation and to follow these instructions carefully
during installation to assure maximum benefit from, and
safe operation, of the blower.
This blower is carefully engineered and must be installed
only as specified. If you modify it or any of its components,
you may cause a fire hazard and will void the WARRANTY.
In addition, such action may void the coverage provided
by the owner's home insurance.
BLOWER
CONTROL
KNOB
GROUND
CLIP
CONTROL
NUT
SPEED
CONTROL
WING
NUT
TEMP.
SENSOR
SWITCH
CAUTION
All wiring should be done by a qualified electrician and shall
be in compliance with local codes and with the National
Electric Code ANSI/NFPA NO. 70-current (in the United
States), or with the current CSA C22.1 Canadian Electric
Code (in Canada).
Shock Risk
Explosion Risk
Do NOT wire 110V to gas control valve.
Do NOT wire 110V to wall switch.
Incorrect wiring will damage millivolt valves.
Incorrect wiring will override IPI safety lockout
and may cause explosion.
WARNING
Attach enclosed wires to the temperature sensor switch/
bracket assembly. The blue wire attaches to the rear of
the bracket and one of the black wires from the variable
speed control attaches closest to the prepunched screw
hole. See Figure 8.23.
Figure 8.22
Disconnect all electrical power. Remove the front door
assembly by lifting off of appliance. Remove the lower
access door. See Figure 8.22.
Figure 8.23
Feed the blue wire and other black wire from the variable
speed control behind the gas valve assembly. Insert the
wires into the slots indicated in Figure 8.28.
Black Wires
Black Wires
Blue Wires
Blue Wires