Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/1228
C. IntelliFire
®
Ignition System Wiring
This appliance requires a 110 VAC supply to the appliance
junction box for operation. A wiring diagram is shown in
Figure 7.2 on the next page.
This appliance is equipped with an IntelliFire
®
control
valve which operates on a 3 volt system.
This appliance is supplied with a 3 volt AC transformer,
which requires the installation of the supplied junction
box.
This appliance is supplied with a battery pack that
requires two D cell batteries (not included). Batteries
cannot be placed in the battery pack while using the 3
volt AC transformer. Conversely, the transformer must be
unplugged if the battery pack is used.
Do not connect this appliance to a thermostat serving
any other appliance.
Bedroom installation in Canada requires this appliance
to be connected to a thermostat.
1. This appliance may be used with a wall switch, wall
mounted thermostat and / or a remote control
2. If using thermostat, use one compatible with a millivolt
gas valve system.
3. Follow parameters for locating thermostat (see individ-
ual thermostat instructions) to ensure proper operation
of appliance.
4. Use low resistance thermostat wire for wiring from
ignition system to the wall switch and thermostat.
5. Use the following chart for wire sizing.
6. Keep wire lengths as short as possible by removing
any excess wire length.
7. Low voltage and 110 VAC voltage cannot be shared
within the same wall box.
8. Ensure the thermostat is mounted level for accurate
readings.
9. The thermostat should be mounted on an inside wall
and not in direct line with the appliance convection air.
10. If the thermostat is located too close to the appli-
ance, you may need to set the temperature setting
slightly higher to maintain the desired temperature
in your home.
Wire Size Max. Length
16 gauge 65 feet
18 gauge 40 feet
20 gauge 25 feet
22 gauge 18 feet
A. Recommendation for Wire
See Figure 7.1 for recommended maximum lead length
(two wire) when using wall thermostat/switch.
7
7
Electrical Information
NOTE: This appliance must be electrically wired and grounded
in accordance with local codes or, in the absence of local
codes, with National Electric Code ANSI/NFPA 70-latest
edition or the Canadian Electric Code, CSA C221.1.
B. Connecting to the Appliance
Wire 110V to electrical junction box.
Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch.
Incorrect wiring will damage millivolt valves.
Incorrect wiring will override IPI safety lockout
and may cause explosion.
WARNING
WARNING
Shock hazard.
This appliance is equipped with a three
This appliance is equipped with a three
pronged (grounding) plug for your protec-
pronged (grounding) plug for your protec-
tion against shock hazard and should be
tion against shock hazard and should be
plugged directly into a prop
plugged directly into a properly grounded
three prong receptacle. Do not cut or remove
the grounding prong from this plug.
Figure 7.1
A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.
NOTICE: Battery polarity must be correct or module
damage will occur.