Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/1222
7. If additional lengths of flex liner are needed to span
the chimney height, use a flex coupler to connect the
pieces of flex liner together. Connect the flex to the
coupler by using four sheet metal screws for each side
(Figure 5.27).
8. Secure the top adapter to the flashing. Use three sheet
metal screws through the side of the top adapter into
the flange on the flashing (Figure 5.28). Twist lock the
high wind termination cap on to the top adapter.
FLEX LINER
FLEX COUPLER
SHEET METAL SCREWS
Figure 5.27
Fire Risk.
Explosion Risk.
Do not let the ex liner sag below the level
at which it will connect to the appliance
or connector. This could allow hot gas to
become trapped and potentially become a
re hazard. The ex liner path should always
be sloped up toward the termination cap.
WARNING
4. To determine the length of flex needed, measure from
3 in. (76 mm) above the top of the flashing down to the
level of the opening. Add the distance from the center
of the chimney out through the wall. Cut a piece of 4
in. (102 mm) flex to this length (extended to its nominal
length). Be sure to leave 2-3 in. (51-76 mm) of flex
above the existing chimney to allow for connection to
the termination kit.
5. Connect the flex liner to the top adapter using four
sheet metal screws (Figure 5.21).
6. Feed the flex liner through the flashing into the
chimney. Carefully feed the flex liner down the chimney
to the bottom and out the opening in the masonry wall,
forming an angle to line up the flex liner with the vent
opening on the appliance.
10 in. x 10 in.
(254 mm x 254 mm)
FRAMED OPENING IN WALL
STUDWALL
MASONRY
CHIMNEY
RETRO
CONNECTOR
FOUR MASONRY BOLTS
(NOT INCLUDED)
WALL THIMBLE COVER
Figure 5.25
3. Secure the flashing to the top of the masonry chimney
using a bead of non-hardening sealant-adhesive. If the
flashing is larger than the top of the chimney, cut and
fold flashing as needed to fit chimney (Figure 5.26).
NOTE: For hearth applications refer to page 20, Figure 5.24
for the use of the 923GCL co-axial to co-linear appliance con-
nector.
CUT AND BEND FLASHING
AS NEEDED TO FIT CHIMNEY
SEALANT-ADHESIVE
Figure 5.26