Page view 26
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. i • 3/13 27
H
1
V
1
Figure 7.4
Figure 7.5
One Elbow
Two Elbows
INSTALLED
HORIZONTALLY
H
1
H
2
V
1
1. Top Vent - Horizontal Termination - (continued)
V
1
Minimum H
1
Maximum
Elbow only 1-1/2 ft. 457 mm
6 in. 152 mm 2-1/2 ft. 610 mm
1 ft. 305 mm 3 ft. 914 mm
2 ft. 610 mm 6 ft 1.8 m
3 ft. 914 mm 9 ft. 2.7 m
4 ft. 1.2 m 12 ft. 3.7 m
5 ft. 1.5 m 15 ft. 4.6 m
6 ft. 1.8 m 18 ft. 5.5 m
V
1
+ H
1
= 50 ft. (15.2 m) Maximum
H
1
= 18 ft. (5.5 m) Maximum
V
1
Minimum H
1
+ H
2
Maximum
Elbow only 6 in. 152 mm
1 ft. 305 mm 2 ft. 610 mm
2 ft. 610 mm 4 ft. 1.2 m
3 ft. 914 mm 9 ft. 2.7 m
4 ft 1.2 m 12 ft. 3.7 m
5 ft. 1.5 m 15 ft. 4.6 m
6 ft. 1.8 m 18 ft. 5.5 m
V
1
+ H
1
+ H
2
= 50 ft. (15.2 m) Maximum
H
1
+ H
2
= 18 ft. (5.5 m) Maximum