- Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
- What to do if you smell gas
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
Heat-N-Glo
Models:
6000TR
6000XLT-CDN
6000ARCH
6000XLS
Installers Guide
WARNING: IMPROPER INSTALLA-
TION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
AGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFOR-
MATION CONSULT A QUALIFIED IN-
STALLER, SERVICE AGENCY, OR THE
GAS SUPPLIER.
525-983C 1/00
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALL-
ERS GUIDE MUST BE LEFT WITH THE APPLI-
ANCE FOR FUTURE REFERENCE.
1. This appliance may be installed in an
aftermarket, permanently located,
manufactured (mobile) home, where not
prohibited by local codes.
2. This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases, unless a certified kit is
used.
Please contact your Heat-N-Glo dealer for any
questions or concerns. For the number of your
nearest
Heat-N-Glo dealer, please call 612-985-6000.
Printed in U.S.A. Copyright 2000,
Heat-N-Glo, a division of Hearth Technologies Inc.
20802 Kensington Boulevard, Lakeville, Mn 55044
WARNING: IF THE INFORMATION
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT
CAUSING PROPERTY DAMAGE,
PERSONAL INJURY, OR DEATH.
Underwriters
Laboratories Listed
1
This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322;
4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia)
543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.
Page view 0
1 2 3 4 5 6 ... 42 43

Summary of Contents

Page 1 - Heat-N-Glo

1- Do not store or use gasoline or other flam-mable vapors and liquids in the vicinity of thisor any other appliance.- What to do if you smell gas D

Page 2

10VENT SYSTEMTERMINATION KITSVENT SYSTEM COMPONENTSFigure 5. Vent Components and TerminationsStep 3Installing theVent SystemA. Vent System ApprovalsT

Page 3 - CONTENTS

11DV-90D65/3257/873/8DV-45D67/1611 1/1661/285/881/251/168/1211 5/885/811 15/16DV-36D35 3/447 3/4DV-48D5 3/48 3/411 3/4DV-12DDV-09DDV-06D6-5/32"(1

Page 4 - Approvals

12Figure 7. Straight Up Vertical VentingSTRAIGHT UPVERTICAL VENTINGV (FT.)40' MAX. (12.4 M)NOTE: Model 6000ARCHA 12-inch length of straight ventp

Page 5 - Preparation

13HORIZONTAL VENTINGHKit No. Max. RunDVK-01DDVK-01TRD 24" (610 mm)NOTE: Models 6000TR and 6000XLS are tested and approved touse 45° elbows in cor

Page 6 - Left Side Front Right Side

14VENTING WITH ONE (1) 90° ELBOW V (FT.) H (FT.) 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX.

Page 7

15VENTING WITH ONE (1) 90° ELBOW V (FT.) H (FT.) 1' MIN. (305mm) 5' MAX. (1.52m) 2' MIN. (610mm) 10' MAX. (3.1m)

Page 8 - Locating the

16VENTING WITH TWO (2) 90° ELBOWSV H H + H11´ MIN. (305 mm) 2´ MAX. (610 mm) 5´ MAX. (1.52m)2´ MIN. (610 mm) 4´ MAX. (1.22 m) 10´ MAX. (3.1m)3´ MIN.

Page 9 - Framing the

17VENTING WITH TWO (2) 90o ELBOWS V (FT.) H + H1 (FT.)1' MIN. (305mm) 5´ MAX. (1.52m)2' MIN. (610mm) 10´ MAX. (3.1m)3' MIN. (

Page 10 - Vent System

181´ MIN. (305 mm) 2´ MAX. (610 mm) 5´ MAX. (1.52 m)2´ MIN. (610 mm) 4´ MAX. (1.22 m) 10´ MAX. (3.1 m)3´ MIN. (914 mm) 6´ MAX. (1.86 m) 15´ MAX. (4.

Page 11

19VENTING WITH THREE (3) 90° ELBOWS V (FT.) H (FT.)1' MIN. (305mm) 5' MAX. (1.52m)2' MIN. (610mm) 10' MAX. (3.1m)3' MIN

Page 12 - STRAIGHT UP

2!!!!!!!!!!!!!!!!!!SAFETY AND WARNING INFORMATIONREAD and UNDERSTAND all instructions carefully before starting the installation.FAILURE TO FOLLOW th

Page 13 - Figure 8. Corner Installation

20Figure 15 For Model 6000TRB. Installing Vent ComponentsFor Model 6000TRAfter determining which set of starting collars will be used(top or rear)

Page 14

21WARNING: ENSURE THAT THE FIBER-GLASS ROPE GASKET SUPPLIED WITHTHE FIREPLACE SEALS BETWEEN THEFIRST VENT COMPONENT & THE OUTERFIREPLACE WRAP.1. A

Page 15 - FOR 6000TR & 6000XLT-CDN

222. Continue Adding Vent ComponentsTo continue adding vent components in accordancewith the pre-planned vent system configuration: Ensure that each

Page 16

23For Vertical Runs - The vent system must besupported every eight (8) feet (2.4 m) above thefireplace flue outlet by wall brackets.To install support

Page 17

24TRIM HEATSHIELD IF TOOLONG, ADD TOSHIELD IF TOOSHORTEXTERIORFIRESTOPINTERIORFIRESTOPHEAT SHIELDFigure 20. 12" x 12" Hole and Vent Pipe2. P

Page 18 - V H H + H

25 Drill a hole or drive a nail through this centerpoint. Check the floor above for any obstructions, such aswiring or plumbing runs. Reposition th

Page 19 - NOTE: V+V

26JOISTCEILING FIRESTOPCEILINGNAILS (4 REQUIRED)!If the area above the ceiling IS an attic, position andsecure the firestop on top of the previously f

Page 20 - For Model 6000TR

27For round captermination:1. Secure the 8-5/8inch (219 mm) pipe,using the exteriorpipelock hole on theround flange of thewall firestop.For trapezoida

Page 21

28V =VENT TERMINALX =AIR SUPPLY INLET=AREA WHERE TERMINAL IS NOT PERMITTEDA = 12" clearances above grade, veranda, porch, deck or balconyB = 12&

Page 22

29!For Vertical Terminations - To locate the vent andinstall the vent sections: Locate and mark the vent centerpoint on the under-side of the roof, a

Page 23

3TABLEOFCONTENTSSafety and Warning Information ... 2Section 1: Approvals and Codes ... 4Approval Listings and

Page 24

30TERMINATIONCAPTo seal the roof hole, and to divert rain and snow fromthe vent system: Attach a flashing to the roof using nails, and use anon-harde

Page 25 - NAILS (4 REQUIRED)

31The diagram below shows how to properly position,level, and secure the fireplace.1. Place the fireplaceinto position.2. Level the fireplacefrom side

Page 26 - C. Vent Termination

32STANDING PILOTNOTE: FLAMES TOOCLOSE TO THECERAMIC INSULATORSCAN CAUSE NUISANCELOCKOUTS ANDELECTRODE FAILURE.DSI IGNITIONFigure 29. Gas Controls Syst

Page 27

33 At the gas line access hole, use insulation to re-pack the space around the gas pipe. Insert insulation from the outside of the fireplaceand pack

Page 28

34NOTE: 6000XLT-CDN DOES NOT HAVE A LIMIT SWITCH.!!Figure 31. Standing Pilot Ignition Wiring DiagramStep 8Wiring theFireplaceNOTE: Electrical wiring m

Page 29

35Figure 32. Fan Wiring DiagramFor Direct Spark Ignition (DSI) WiringAppliance RequirementsThis appliance requires that 110-120 VAC be wired tothe fa

Page 30 - TERMINATION

36Figure 33. Direct Spark Ignition (DSI) Wiring DiagramStep 9FinishingThe following diagram shows the minimum verticaland corresponding maximum horizo

Page 31

37CAUTIONIF JOINTS BETWEEN THE FINISHED WALLS ANDTHE FIREPLACE SURROUND (TOP AND SIDES)ARE SEALED, A 300° F. MINIMUM SEALANTMATERIAL MUST BE USED. TH

Page 32 - Supply Line

38Positioning the LogsIf the gas logs have been factory installed theyshould not need to be positioned.If the logs have been packaged separately, refe

Page 33 - ACCESS HOLE

391. Lift the trim door upand out of the unit.EYE BOLTLATCH BRACKETGLASS DOORFigure 38. Placement of the Ember MaterialCAUTIONIT IS STRONGLY RECOMMEND

Page 34 - Fireplace

4Approval Listingsand CodesAppliance CertificationThe Heat-N-Glo models discussed in this InstallersGuide have been tested to certification standardsa

Page 35

40Before lighting the fireplace, be sure to do thefollowing:Remove all paperwork and documents from thefireplace.Review safety warnings and cautions

Page 36 - Finishing

41This model is equipped with a baffle which will allow youto control usable heat output. The baffle control lever islocated at the lower left corner

Page 37 - Ember Material

424MaintainingandServicingYourFireplaceFireplaceMaintenanceAlthough the frequency of your fireplace servicing andmaintenance will depend on use and th

Page 38

43STANDING PILOTFigure 41. Burner Flame PatternsMAKE SURE THE FLAMESARE STEADYNOTLIFTING OR FLOATING.Figure 42. Pilot/Ignitor Flame PatternsDSI IGNIT

Page 39 - GLASS DOOR

52GettingStartedHeat-N-Glo direct vent gas fireplaces are designed tooperate with all combustion air siphoned from outsideof the building and all exha

Page 40

6Figure 1. Diagram of the 6000TR, 6000XLT-CDN and 6000XLSThe Heat-N-Glo Warranty will be voided by, and Heat-N-Glo disclaims anyresponsibility for, th

Page 41 - Installation

7Figure 2. Diagram of the 6000ARCH

Page 42 - IMPORTANT

83Installing theFireplaceStep 1Locating theFireplaceThe diagram below shows space and clearancerequirements for locating a fireplace within a room.MOD

Page 43 - INSULATOR

9ABCFraming should beconstructed of 2 X 4lumber or heavier.Model A B C D E6000TR 42 38 1/4 22 42 26 1/46000XLS 42 38 1/4 22 N/A 26 1/46000XLT-CDN 42