Heat & Glo • SLR • 2143-900 Rev. B • 7/08 1
Model:
SLR (Cosmo)
DO NOT store or use gasoline or other am-
mable vapors and liquids in the vicinity of this
or any other appliance.
What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor’s phone. Follow the gas suppli-
er’s instructions.
- If you cannot reach your gas supplier, call
the re department.
Installation and service must be performed
by a quali ed installer, service agency, or the
gas supplier.
WARNING: If the information in these
instructions is not followed exactly, a re
or explosion may result causing property
damage, personal injury, or death.
Owners Manual
Installation and Operation
DO NOT DISCARD THIS MANUAL
NOTICE
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer’s instructions
and the manufactured home construction and safety standard,
Title 24 CFR, Part 3280 or Standard for Installation in Mobile
Homes, CAN/CSA Z240MH, in Canada.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
Installation and service of this appliance should be
performed by quali ed personnel. Hearth & Home
Technologies suggests NFI certi ed or factory trained
professionals, or technicians supervised by an NFI
certi ed professional.
Leave this manual with
party responsible for use
and operation.
DO NOT
DISCARD
WARNING
• Important operating
and maintenance
instructions included.
Read, understand and follow
these instructions for safe
installation and operation.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
This appliance has been supplied with an integral barrier
to prevent direct contact with the xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
DO NOT touch glass until it is cooled
NEVER allow children to touch glass
• Keep children away
CAREFULLY SUPERVISE children in same room as
replace.
Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other ammable
materials.
Keep clothing, furniture, draperies and other ammable
materials away.
Page view 0
1 2 3 4 5 6 ... 66 67

Summary of Contents

Page 1 - Owner’s Manual

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 1Model:SLR (Cosmo)• DO NOT store or use gasoline or other fl am-mable vapors and liquids in the

Page 2 - A. Congratulations

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 10H. Lighting Instructions (IPI)The IPI system may be operated with two D-cell batteries. When u

Page 3 - User Guide

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 11Initial Break-in Procedure• The fireplace should be run three to four hours continuously on hi

Page 4 - 16 Reference Materials

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 12Glass CleaningFrequency: SeasonallyBy: HomeownerTools Needed: Protective gloves, glass cleaner,

Page 5 - B. Limited Lifetime Warranty

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 13VentingFrequency: SeasonallyBy: HomeownerTools needed: Protective gloves and safety glasses.

Page 6 - Listing and Code Approvals

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 14A. Typical Appliance SystemNOTICE: Illustrations and photos refl ect typical installations and a

Page 7 - Massachusetts

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 15B. Design and Installation ConsiderationsHeat & Glo direct vent gas appliances are design

Page 8

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 165 5 Framing and Clearances A. Selecting Appliance LocationWhen selecting a location for the ap

Page 9 - Figure 2.2 Clear Space

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 17B. Constructing the Appliance ChaseA chase is a vertical box-like structure built to enclose

Page 10 - WARNING:

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 18D. Mantel and Wall ProjectionsWARNING! Risk of Fire! Comply with all minimum clear-ances to com

Page 11 - J. Frequently Asked Questions

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 191/2 in.SHEETROCK3-1/2 in.1 in.AIR SPACENON-COMBUSTIBLEBOARD SHIPPED WITH APPLIANCE1-9/16 in.Fi

Page 12 - Maintenance and Service

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 2Listing Label Information/LocationModel Name: ___________________________________________ Date pu

Page 13

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 20Figure 6.3 Leveled Termination CapsA. Vent Termination Minimum ClearancesRoof Pitch H (Min.)

Page 14 - Installer Guide

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 21ONPRQV= VENT TERMINALX= AIR SUPPLY INLET= AREA WHERE TERMINAL IS NOT PERMITTEDFigure 6.4 Min

Page 15 - C. Tools and Supplies Needed

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 22A. Approved PipeThis appliance is approved for use with Hearth & Home Technologies SLP venti

Page 16 - Framing and Clearances

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 23Figure 7.4Top Vent - Horizontal TerminationVenting with 1 elbowH1V1V MinimumH1 MaximumSLR90 El

Page 17 - Millimeters

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 24INSTALLEDHORIZONTALLYH1H2V1Figure 7.51. Top Vent - Horizontal Termination - (continued)Top Ven

Page 18 - 1-9/16 in

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 25H2H1V2V1Top Vent - Horizontal TerminationVenting with 3 elbowsNote: Use SLP Series components

Page 19 - 3-1/2 in

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 26Figure 7.71. Top Vent - Horizontal Termination - (continued)Top Vent - Horizontal TerminationV

Page 20 - Termination Locations

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 27Figure 7.8 Vertical Vent MaximumNote: If installing a vertical vent/termination off the top o

Page 21 - Covered Alcove Applications

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 28Figure 7.11H1V1V2Top Vent - Vertical TerminationVenting with 2 elbowsNote: Use SLP Series compon

Page 22 - Effective

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 29Figure 7.12INSTALLEDHORIZONTALLYH1H2V1V2Top Vent - Vertical TerminationVenting with 3 elbowsNo

Page 23 - Venting with 1 elbow

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 3 Safety Alert Key:• DANGER! Indicates a hazardous situation which, if not avoided will resul

Page 24 - Venting with 2 elbows

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 30Top Vent - Vertical TerminationVenting with 4 elbowsNote: Use SLP Series components only.Note: T

Page 25 - Venting with 3 elbows

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 31* When using SLP pipe, minimum clearances from the vent pipe to combustible materi-als at insi

Page 26

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 32C. Install the Ceiling FirestopA ceiling fi restop MUST be used between fl oors and attics.• SL

Page 27 - No Elbows

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 33D. Install Attic Insulation ShieldWARNING! Fire Risk. DO NOT allow loose materials or insulat

Page 28

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 34ELBOW HEAT SHIELD SHOWNIN SHIPPING POSITIONCAUTION! Risk of Cuts, Abrasions or Flying Debris. We

Page 29

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 35B. Securing and Leveling the ApplianceWARNING! Risk of Fire! Prevent contact with:• Sagging

Page 30 - Venting with 4 elbows

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 3610 10 Installing Vent Pipe (SLP Pipe) Figure 10.2 High Temperature Silicone SealantA. Assembl

Page 31 - B. Wall Penetration Framing

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 37C. Secure The Vent SectionsFigure 10.5 Securing Vertical Pipe SectionsFigure 10.6 Securing

Page 32

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 38D. Disassemble Vent Sections• Rotate either section (see Figure 8.7) so the seams on both pipe

Page 33

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 39F. Install Metal Roof FlashingNote: Skip this section if using the RF4-8.• See minimum vent h

Page 34 - Appliance Preparation

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 4Î = Contains updated information.13 Finishing A. Framing and Finishing Instructions . . . .

Page 35 - BOTH SIDES

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 40H. Install RF4-8The RF4-8 may be used in place of the roof fl ashing and storm collar (Sections 1

Page 36 - A. Assemble Vent Sections

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 41SCREWSCAULKSTORM COLLAR(1 of 3)Figure 10.20TERMINATION CAPI. Install Vertical Termination Cap

Page 37 - B. Assemble Slip Sections

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 42Figure 10.22 Venting through the wallNote: When using termination caps with factory-supplied h

Page 38 - D. Disassemble Vent Sections

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 43A. Fuel Conversion• Make sure the appliance is compatible with available gas types.• Conversi

Page 39

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 44C. Gas Connection • Refer to Reference Section 16 for location of gas line access in appliance.

Page 40 - H. Install RF4-8

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 45FIREBOX BOTTOMFIREBOX BOTTOMA. Wiring RequirementsNOTICE: This appliance must be electrically

Page 41 - Termination

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 46Figure 12.2 Intellifi re Pilot Ignition (IPI) Wiring Diagram with Wall Switch or ThermostatFigur

Page 42

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 4713 13 Finishing Finishing InstructionsIt is important to follow the framing and fi nishing ins

Page 43 - Gas Information

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 48WARNING! Risk of Fire! Maintain specifi ed air space clearances to combustibles.Failure to comply

Page 44 - C. Gas Connection

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 49Sealing JointsThe joints between the drywall sides and drywall above the top factory installe

Page 45 - Electrical Information

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 5B. Limited Lifetime Warranty© 2007 Hearth & Home Technologies Inc.LIMITED LIFETIME WARRANT

Page 46 - E. Junction Box Installation

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 50B. Mantel and Wall ProjectionsWARNING! Risk of Fire! Comply with all minimum clear-ances to com

Page 47 - Finishing

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 51C. Facing Material• Facing and/or fi nishing materials must not interfere with air fl ow through

Page 48 - FINISHING

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 520 in.0 in.0 in.NON-COMBUSTIBLEBOARDTop JointSideJointBottomJointNon-CombustibleFinishing Materia

Page 49

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 53Only doors certifi ed for use with this appliance model may be used. Contact your dealer for a

Page 50 - UNLIMITED

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 54A. Remove Fixed Glass AssemblySee Section 14F.B. Remove the Shipping MaterialsRemove shipping

Page 51 - C. Facing Material

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 55E. Rock Media InstructionsCAUTIONSharp Edges• Wear protective gloves and safety glasses duri

Page 52 - 3/4 IN

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 566. Place the fl at pieces of Rock Media that were sorted out in Step 1, carefully hide the pilot

Page 53 - (MT-SLR-**)

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 57H. Air Shutter SettingAir shutter settings may be adjusted by a qualifi ed install-er at the t

Page 54 - Appliance Setup

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 58A. Intellifi re Ignition SystemSymptom Possible Cause Corrective Action1. Pilot won’t light. The

Page 55 - E. Rock Media Instructions

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 59Intellifi re Ignition System - (continued)Symptom Possible Cause Corrective Action4. Pilot ligh

Page 56 - Figure 14.5. Remove Screw

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 6C. BTU Specifi cationsMODEL: SLRLABORATORY: Underwriters Laboratories, Inc. (UL)TYPE: Vented Gas

Page 57 - UPPER SPRING LATCH

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 6016 16 Reference Materials A. Appliance Dimension DiagramDimensions are actual appliance dimen

Page 58 - Troubleshooting

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 61Cap ShieldDRC-RADIUS13-7/8 in.(352 mm)9-1/2 in.(241 mm)14 in.(356 mm)COOL-ADDCap Shield11-5/8

Page 59

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 628-3/4 in.222 mm6-1/2 in.165 mm6-5/8 in.168 mm6 in.152 mm6-1/2 in.165 mm6-5/8 in.168 mm9-7/8 in.2

Page 60 - Reference Materials

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 63SLK-SNKDSnorkelTermination CapSLP-TVHWVerticalTermination CapPVK-80Power VentSLP-TRAP2Horizont

Page 61 - B. Vent Components Diagrams

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 64C. Service PartsSLRBeginning Manufacturing Date: July 2008Ending Manufacturing Date: ______ Ser

Page 62 - Effective Height/Length

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 65C. Service Parts List SLRIMPORTANT: THIS IS DATED INFORMATION. When requesting service or re

Page 63

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 66Service PartsSLRBeginning Manufacturing Date: July 2008Ending Manufacturing Date: ______ Valve

Page 64 - C. Service Parts

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 67Heat & Glo, a brand of Hearth & Home Technologies Inc. 20802 Kensington Boulevard, Lak

Page 65 - Stocked

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 7G. Requirements for the Commonwealth of MassachusettsFor all side wall horizontally vented gas

Page 66 - IPI Valve Assembly

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 8Figure 2.1 General Operating PartsB. Your FireplaceWARNING! DO NOT operate fi replace before read

Page 67 - DO NOT DISCARD THIS MANUAL

Heat & Glo • SLR • 2143-900 Rev. B • 7/08 9C. Clear SpaceWARNING! DO NOT place combustible objects in front of the fi replace or block louv