Heat & Glo • ST-42TVFL-IPI • 455-902 Rev. C • 12/07Model:ST-42TVFL-IPI1Owner’s ManualInstallation and Operation• Do not store or use gasolin
Minimum Clearances from the B-Type Vent Pipeto Combustible Materials is 1 inch (25 mm) allaround the pipe.Step 2Framing theFireplaceFireplace framing
11Heat & Glo • ST-42TVFL-IPI • 455-902 Rev. C • 12/07Step 3NegativePressureMake-up AirNegative Pressure warning: When negative pressureis p
Detailed installation instructions for Model AK-TVOutside Air kit are found in the kit.Air DamperBefore lighting the burner, open the damper plateby s
13Heat & Glo • ST-42TVFL-IPI • 455-902 Rev. C • 12/07Step 4Installing theVent SystemA. Vent System ApprovalsThese fireplaces are approved t
Figure 6. Vent System Attachment!WARNING: THIS GAS FIREPLACEMUST NEVER BE VENTED BYCONNECTING TO A CHIMNEY FLUESERVING A SEPARATE SOLID FUELBURNING
15Heat & Glo • ST-42TVFL-IPI • 455-902 Rev. C • 12/07C. Bedroom Installation in CanadaThis model MUST NOT be vented into a ventsystem insta
The diagram below shows how to properly position,level, and secure the fireplace.1. Place the fireplaceinto position.2. Level the fireplacefrom side t
17Heat & Glo • ST-42TVFL-IPI • 455-902 Rev. C • 12/07Step 7The GasSupply LineNOTE: Have the gas supply line installed inaccordance with loca
• At the gas line access hole, use insulation to re-pack the space around the gas pipe.• Insert insulation from the outside of the fireplace andpack t
19Heat & Glo • ST-42TVFL-IPI • 455-902 Rev. C • 12/07!!Step 9Wiring theFireplaceNOTE: Electrical wiring must be installed by alicensed elect
2Heat & Glo • ST-42TVFL-IPI • 455-902 Rev. C • 12/07!SAFETY AND WARNING INFORMATIONREAD and UNDERSTAND all instructions carefully before sta
Heat & Glo • ST-42TVFL-IPI • 455-902 Rev. C • 12/07Figure 10. Intermittent Pilot Ignition (IPI) Wiring DiagramFor Intermittent Pilot Ignitio
Heat & Glo • ST-42TVFL-IPI • 455-902 Rev. C • 12/07If the box is being wired to a wall mounted switch for usewith a fan (See Figure 11):• T
22Heat & Glo • ST-42TVFL-IPI • 455-902 Rev. C • 12/07!Step 10FinishingThe following diagram shows the minimum verticaland corresponding maxi
Step 11Installing Trim,Logs, and EmberMaterialFigure 13. Sealant MaterialHearth ExtensionsA hearth extension may be desirable for aestheticreasons. Ho
Figure 14. Placement of the Ember MaterialPlacing the Ember MaterialEmber material is shipped with this gas fireplace. Thebag labeled Golden Ember (GE
Step 12Before Lightingthe FireplaceBefore lighting the fireplace, be sure to do the following:Remove all paperwork and documents fromunderneath the fi
4MaintainingandServicingYourFireplaceType of Fireplace Maintenance Task ToMaintenance Frequency By Be CompletedReplacing Once annually, Qualified Brus
Heat & Glo, a brand of Hearth & Home Technologies Inc.20802 Kensington Boulevard, Lakeville, MN 55044www.heatnglo.comContact InformationPlease
3Heat & Glo • ST-42TVFL-IPI • 455-902 Rev. C • 12/07Table ofContentsSafety and Warning Information... 2Service Parts List ...
4Heat & Glo • ST-42TVFL-IPI • 455-902 Rev. C • 12/074Log Set AssemblyService Parts DiagramService PartsST-42TVFL-IPIBeginning Manufacturing
Valve Assembly Diagram/Parts ListService PartsBeginning Manufacturing Date: July 2002Ending Manufacturing Date: ______ST-42TVFL-IPI5Heat & Glo
Approval Listingsand CodesAppliance CertificationThe Heat & Glo fireplace models discussed in thisInstallers Guide have been tested to certificati
7Heat & Glo • ST-42TVFL-IPI • 455-902 Rev. C • 12/072GettingStartedIntroducing theHeat & GloGas FireplacesHeat & Glo B-type vent gas
8Heat & Glo • ST-42TVFL-IPI • 455-902 Rev. C • 12/07Figure 1. Diagram of the ST-42TVFL-IPIWhen planning a fireplace installation, it’s neces
Figure 3. Fireplace Locations and Space RequirementsClearance RequirementsThe top, back, and sides of the fireplace aredefined b