1Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13Model:SLR32• DO NOT store or use gasoline or other fl am-mable vapors and liquids in the vicinit
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1310C. Clear SpaceWARNING! DO NOT place combustible objects in front of the fi replace or block louv
11Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13H. Lighting Instructions (IPI)The IPI system may be operated with two D-cell batteries. When
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1312Initial Break-in Procedure• The fireplace should be run three to four hours continuously on hig
13Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13Glass CleaningFrequency: SeasonallyBy: HomeownerTools Needed: Protective gloves, glass cleaner
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1314VentingFrequency: SeasonallyBy: HomeownerTools needed: Protective gloves and safety glasses.•
15Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13A. Typical Appliance SystemNOTICE: Illustrations and photos refl ect typical installations and
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1316B. Design and Installation ConsiderationsHeat & Glo direct vent gas appliances are designe
17Heat & Glo • SLR32 • 2269-900 Rev. H • 6/135 5 Framing and Clearances A. Selecting Appliance LocationWhen selecting a location for the a
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1318B. Constructing the Appliance ChaseA chase is a vertical box-like structure built to enclose t
19Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13C. ClearancesNOTICE: Install appliance on hard metal or wood surfaces extending full width and
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/132Listing Label Information/LocationModel Name: ___________________________________________ Date p
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1320D. Mantel and Wall ProjectionsWARNING! Risk of Fire! Comply with all minimum clear-ances to co
21Heat & Glo • SLR32 • 2269-900 Rev. H • 6/131/2 IN. THICK WALL SHEATHING5 IN.1 IN.AIR SPACENON-COMBUSTIBLE BOARD SHIPPED WITH APPLIANCE1 IN
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1322A. Vent Termination Minimum ClearancesRoof Pitch H (Min.) Ft.Flat to 6/12...
23Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13Figure 6.3 Minimum Clearances for TerminationONPRQX= AIR SUPPLY INLETA = 12 inches...
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1324A. Approved PipeThis appliance is approved for use with Hearth & Home Technologies SLP vent
25Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13Figure 7.4Top Vent - Horizontal TerminationVenting with 1 elbowH1V1V MinimumH1 MaximumSLR3290 E
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1326INSTALLEDHORIZONTALLYH1H2V1Figure 7.51. Top Vent - Horizontal Termination - (continued)Top Ve
27Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13H2H1V2V1Top Vent - Horizontal TerminationVenting with 3 elbowsNote: Use SLP Series components o
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1328Figure 7.7 Vertical Vent MaximumNote: If installing a vertical vent/termination off the top of
29Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13Figure 7.10H1V1V2Top Vent - Vertical TerminationVenting with 2 elbowsNote: Use SLP Series compo
3Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13 Safety Alert Key:• DANGER! Indicates a hazardous situation which, if not avoided will result
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1330Figure 7.11INSTALLEDHORIZONTALLYH1H2V1V2Top Vent - Vertical TerminationVenting with 3 elbowsNot
31Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13Top Vent - Vertical TerminationVenting with 4 elbowsNote: Use SLP Series components only.Note:
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1332Clearances to Combustibles:Refer to Section 5 for clearances to the appliance, man-tel, mantel
33Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13EXISTING CHIMNEYHEARTHFLOOREXISTING CHIMNEYEXHAUST AIR VENT PIPEINLET AIR VENT PIPETo minimize
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1334* When using SLP pipe, minimum clearances from the vent pipe to combustible materi-als at insid
35Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13C. Install the Ceiling FirestopA ceiling fi restop MUST be used between fl oors and attics.• S
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1336D. Install Attic Insulation ShieldWARNING! Fire Risk. DO NOT allow loose materials or insulati
37Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses du
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1338NAILING TABSBOTH SIDESB. Securing and Leveling the ApplianceWARNING! Risk of Fire! Prevent con
39Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1310 10 Installing Vent Pipe (SLP Pipe) Figure 10.2 High Temperature Silicone SealantA. Assemb
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/134 = Contains updated information.13 Finishing A. Framing and Finishing Instructions . . . .
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1340Figure 10.5 Securing Vertical Pipe SectionsFigure 10.6 Securing Horizontal Pipe SectionsB. A
41Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13D. Disassemble Vent Sections• Rotate either section (see Figure 10.7) so the seams on both pi
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1342F. Install Metal Roof Flashing• See minimum vent heights for various pitched roofs (Figure 10.
43Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13SCREWSCAULKSTORM COLLAR(1 of 3)Figure 10.15TERMINATION CAPH. Install Vertical Termination Cap•
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1344Figure 10.17 Venting through the wallNote: When using termination caps with factory-supplied
45Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1311 11 Gas Information A. Fuel Conversion• Make sure the appliance is compatible with availab
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1346C. Gas Connection • Refer to Reference Section 16 for location of gas line access in appliance
47Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13A. Wiring RequirementsNOTICE: This appliance must be electrically wired and grounded in accorda
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1348Figure 12.2 IntelliFire Pilot Ignition (IPI) Wiring Diagram with Wall Switch or ThermostatE.
49Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1313 13 Finishing A. Framing and Finishing InstructionsWARNING! Risk of Fire! Comply with all m
5Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13B. Limited Lifetime Warranty4021-645F 02-18-13 Page 1 of 2Hearth & Home TechnologiesLIMIT
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1350WARNING! Risk of Fire! Maintain specifi ed air space clearances to combustibles.Failure to compl
51Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13Note: The lower cover panel must be pushed all the way down. The outer fi nishing fl anges shou
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1352B. Mantel and Wall ProjectionsWARNING! Risk of Fire! Comply with all minimum clear-ances to co
53Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13Non-Combustible Finish Materials0 - 1 inch thickness-Overlap Fit MethodBoth the Tonic and Marti
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1354Non-Combustible Finish Material 0-4 Inches Thick Bottom Joint3/4 IN. 3/4 IN. 3 IN.Figure 13.11
55Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13D. Decorative FrontsWARNING! Risk of Fire! A decorative front is required for this model. DO N
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1356A. Remove Fixed Glass AssemblySee Section 14.F.B. Remove the Shipping MaterialsRemove shippin
57Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13Figure 14.3. Placing Glass Rock Media on Pilot Shield WARNING! Risk of Fire! DO NOT place glas
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1358H. Air Shutter SettingAir shutter settings may be adjusted by a qualifi ed install-er at the ti
59Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13A. IntelliFire Ignition SystemSymptom Possible Cause Corrective Action1. Pilot won’t light. Th
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/136B. Limited Lifetime Warranty (continued)4021-645F 02-18-13 Page 2 of 2WARRANTY CONDITIONS:•
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1360IntelliFire Ignition System - (continued)Symptom Possible Cause Corrective Action4. Pilot light
61Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1316 16 Reference Materials A. Appliance Dimension DiagramDimensions are actual appliance dime
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1362Cap ShieldDRC-RADIUS13-7/8 in.(352 mm)9-1/2 in.(241 mm)14 in.(356 mm)COOL-ADDMCap Shield11-5/8
63Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13B. Vent Components Diagrams (continued)Figure 16.3 SLP Series Vent Components 26 in.660
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1364B. Vent Components Diagrams (continued)Figure 16.4 SLP Series Vent Components SLP90SL-2D
65Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1313 in.(330 mm)15 in.(381 mm)8-1/8 in.(206 mm)10-7/8 in.276 mm10-1/2 in.267 mm3°87°Effective Len
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1366Figure 16.6 Coaxial to Colinear Vent ComponentsLINK-DV30BFlex Liner KitDV-46DVA-GCLCoaxial/Col
67Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13Service PartsBeginning Manufacturing Date: Oct 2011 Ending Manufacturing Date: ActiveSLR32IMPOR
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1368Service PartsBeginning Manufacturing Date: Oct 2011 Ending Manufacturing Date: ActiveSLR32IMPOR
69Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13Service PartsBeginning Manufacturing Date: Oct 2011 Ending Manufacturing Date: ActiveSLR32IMPOR
7Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13C. BTU Specifi cationsMODEL: SLR32LABORATORY: Underwriters Laboratories, Inc. (UL)TYPE: Vented
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/1370Heat & Glo, a brand of Hearth & Home Technologies 7571 215th Street West, Lakeville, MN
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/138H. Requirements for the Commonwealth of MassachusettsFor all side wall horizontally vented gas f
9Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13Figure 2.1 General Operating PartsB. Your FireplaceWARNING! DO NOT operate fi replace before rea
Comments to this Manuals